PubMed چکیده/رکورد

An in-body networking system for communication between wearable and implantable therapeutics.

استودیوی صوتی مقاله

پخش حرفه‌ای فارسی و انگلیسی

در حال بررسی نسخه‌های صوتی ذخیره‌شده…

صوت تولیدشده با هوش مصنوعی است. برای کاربرد علمی یا درمانی، متن و منبع اصلی را بررسی کنید.
خواندن هوشمند فارسی و انگلیسی در حال آماده‌سازی صداهای مرورگر…
تنظیم صدای طبیعی و سرعت

صداهایی که در نامشان «Natural»، «Neural» یا «Online» دیده می‌شود معمولاً طبیعی‌ترند. انتخاب صدا به صداهای نصب‌شده در ویندوز و مرورگر شما بستگی دارد.

چکیده اصلی

Networks of bioelectronic sensors and actuators enable closed-loop therapies that connect distant, related physiological dynamics. Currently, device interactions are limited by communication methods that inefficiently penetrate tissue and require bulky components. Inspired by the ionic signaling of the nervous system, we engineered a communication platform that uses tissue as a conductive medium to transmit signals among implants and wearables through epidermal, subcutaneous, intraperitoneal, and gastrointestinal spaces. Devices generate transient electric fields that selectively activate other devices when receiving pulses that switch on their specific transistor circuits. Implants are syringe-injectable, require negligible power consumption in listening states, and provide >10× greater tissue communication coverage than Bluetooth. In vivo in rats, we demonstrate coordinated, full-body networks of sensors and neural interfaces that enable wireless dual-limb motor control.

متن کامل اصلی

متن در JumpToDate ذخیره نشده است.

برای بررسی دسترسی کتابخانه‌ای یا خرید، رکورد اصلی را باز کنید.

رفتن به منبع اصلی
در همین زیرشاخه

مقاله‌های مرتبط

PubMed2027

Skeletal Muscle Tissue Engineering: Methods and Analysis for the Bio-Fabrication and Validation of a 3D Scaffold-Free Muscle Construct.

The development of three-dimensional (3D) tissue constructs that accurately replicate the morphology and function of native tissues is critical for advancing tissue engineering and regenerative medicine. Two primary strategies are currently employed: scaffold-based and scaffold-free approaches. Both aim to reproduce a biomimetic microenvironment that supports cell-cell and cell-matrix interactions, enabling the formation of functional …

PubMed2026

Effects of Orthotic Interventions on Pain, Balance, and Plantar Pressure in Flexible Flatfoot: A Systematic Review.

OBJECTIVE: To systematically review the evidence for orthotic interventions on pain, balance, and plantar pressure distribution in individuals with flexible flatfoot. METHODS: Randomized and nonrandomized controlled trials of orthotic interventions for flexible flatfoot were included. Primary outcomes were pain, balance, and plantar pressure. MEDLINE via PubMed, EMBASE via Elsevier, and the Cochrane Library were searched from inception…

PubMed2026

Capsulectomy at Explant: Rethinking Spinal Cord Stimulator Infected Generator Pocket Management in the Immunocompromised-A Case Series.

BACKGROUND: Surgical site infections (SSI) associated with spinal cord stimulation (SCS) implants pose risks of morbidity, mortality, and increased healthcare costs. Immunocompromised patients are especially vulnerable due to impaired immune responses, delaying diagnosis and increasing complications. Current guidelines recommend SCS explantation for deep or inadequately treated superficial SSI, though the role of capsulectomy remains u…

PubMed2026

The "Spiked Helmet Sign" on Electrocardiogram Following Left Ventricular Assist Device Implantation: A Case Report.

BACKGROUND: The ECG "Spiked Helmet Sign," with diffuse concave ST-segment elevation and a J-point spike, typically suggests acute pericarditis. However, after LVAD implantation, it may herald a localized pericardial hematoma and impending tamponade. CASE PRESENTATION: A 68-year-old male with end-stage ischemic cardiomyopathy underwent LVAD placement. Hours postoperatively, ECG showed this sign with QTc prolongation (578 ms). Bedside ec…