Mapping the Evidence on Midline Catheter Tip Location, Confirmation Methods and Associated Characteristics: A Scoping Review.
پخش حرفهای فارسی و انگلیسی
در حال بررسی نسخههای صوتی ذخیرهشده…
تنظیم صدای طبیعی و سرعت
صداهایی که در نامشان «Natural»، «Neural» یا «Online» دیده میشود معمولاً طبیعیترند. انتخاب صدا به صداهای نصبشده در ویندوز و مرورگر شما بستگی دارد.
چکیده اصلی
BACKGROUND: Midline catheters (MCs) are increasingly utilized as an alternative to peripheral and central venous catheters. However, the lack of standardized protocols for tip location and confirmation methods remains a significant barrier to patient safety and clinical decision-making. AIM: This scoping review aimed to systematically map the current evidence and evolving clinical practices regarding MC tip placement, specifically exploring tip location standards, confirmation methods and associated clinical characteristics. DESIGN: Scoping review. REVIEW METHODS: The scoping review was conducted following the Arksey and O'Malley framework and PRISMA-ScR reporting guidelines. Two independent reviewers conducted screening and data extraction, with descriptive methods used for synthesis. DATA SOURCES: Eleven databases (platforms) were searched from inception to 31 August 2026: the Cochrane Library, PubMed, EMBASE, Web of Science, Scopus, ProQuest, CINAHL, CNKI, Wanfang Data, SinoMed and VIP databases. RESULTS: Out of 762 initial records, 41 publications met eligibility criteria. North American guidelines strictly restrict MC tips to the peripheral axilla, whereas European consensus advocates for deeper placement into the thoracic axillary or subclavian veins. Tip confirmation practices are heterogeneous. Methods range from external anatomical measurement to ultrasound guidance and post-procedural radiography. A significant limitation identified is the reduced reliability of ultrasound for tip visualization in patients with morbid obesity, often necessitating alternative confirmation or resulting in indeterminate placement. The quality and comparability of outcome data across studies were limited by inconsistent tip location definitions, heterogeneous patient populations and variable follow-up durations. CONCLUSION: This review highlights substantial heterogeneity in clinical practice and guideline recommendations. The association between tip position and catheter-related complications is multifactorial. This scoping review identifies that current evidence is inadequate to support a clear preference for any single midline catheter tip-positioning strategy. These findings set an agenda for future research to inform standardized, evidence-based midline catheter practice guidelines. IMPLICATIONS FOR THE PROFESSION: Clinical nurses and vascular access specialists should be aware of divergent international guideline suggestions for midline catheter tip positioning. Consensus-based definitions for implantation depth and target veins, together with consistent anatomical terminology, are needed to support cross-study comparison. Optimized multimodal tip-confirmation workflows may reduce unnecessary X-ray use and improve safety, supported by targeted education and interprofessional collaboration. Future prospective cohort studies and comparative trials are needed to evaluate the relationship between tip location, confirmation strategies and patient-important clinical outcomes. IMPACT: This scoping review synthesizes existing international literature on midline catheter tip-related practices and exposes inconsistencies across guideline documents. It draws attention to key unresolved clinical questions and provides clear directions for subsequent primary research. The findings may support the development of future consensus statements and help reduce practice variation in midline catheter care. REPORTING METHOD: PRISMA-ScR. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution. REVIEW PROTOCOL REGISTRATION: https://osf.io/fn8vz/overview.
نتیجه فارسی
این مرور جامع نشان میدهد که بین شیوههای بالینی و دستورالعملهای بینالمللی اختلافنظر وجود دارد و شواهد فعلی کافی برای ترجیح یک استراتژی واحد برای موقعیتدهی نوک سوند میانی نیست. توافق بر سر تعاریف و اصطلاحات آناتومیک مورد نیاز است.
- موقعیتدهی نوک سوند میانی بین آمریکای شمالی و اروپا متفاوت است.
- روشهای تأیید نوک متنوع و شامل رادیوگرافی و هدایت فراصوت است.
- هدایت فراصوت در بیماران چاق مفرط کماعتمادتر است.
- تعاریف ناهمگون موقعیت نوک کیفیت دادهها را محدود کرده است.
ترجمه فارسی چکیده
سوندهای میانی (MC) بهطور فزایندهای بهعنوان جایگزینی برای سوندهای وریدی محیطی و مرکزی استفاده میشوند. با این حال، فقدان پروتکلهای استاندارد برای موقعیت نوک و روشهای تأیید مانعی مهم برای ایمنی بیمار و تصمیمگیری بالینی است. این مرور جامع بهطور سیستماتیک شواهد فعلی و شیوههای بالینی در حال تغییر را در مورد قرارگیری نوک سوند میانی، بهویژه استانداردهای موقعیت نوک، روشهای تأیید و ویژگیهای بالینی مرتبط، بررسی میکند. این مرور بر اساس چارچوب آرسکی و اومالی و دستورالعملهای گزارشدهی PRISMA-ScR انجام شد. نتایج نشان داد که دستورالعملهای آمریکای شمالی نوک سوند میانی را به عروق محیطی زیربغل محدود میکنند، در حالی که توافق اروپایی برای قرارگیری عمیقتر در عروق زیربغلی یا زیربینی توصیه میکند. روشهای تأیید نوک متنوع هستند و از اندازهگیری آناتومیک خارجی تا هدایت فراصوت و رادیوگرافی پس از عمل متغیر است. محدودیت مهمی شناسایی شد که هدایت فراصوت برای نمایش نوک در بیماران دارای چاقی مفرط کماعتمادتر است. کیفیت و قابل مقایسه بودن دادههای خروجی در مطالعات محدود به تعاریف ناهمگون موقعیت نوک، جمعیتهای بیمار متنوع و مدتهای پیگیری متغیر بود.
روش پژوهش
این مرور جامع بر اساس چارچوب آرسکی و اومالی و دستورالعملهای گزارشدهی PRISMA-ScR انجام شد. دو نویسنده مستقل screening و استخراج دادهها را انجام دادند.
محدودیتها
محدودیتهای شامل تعاریف ناهمگون موقعیت نوک، جمعیتهای بیمار متنوع و مدتهای پیگیری متغیر بود که کیفیت و قابل مقایسه بودن دادههای خروجی را محدود کرد. همچنین هدایت فراصوت در بیماران چاق مفرط کماعتمادتر است.
نمای PICO و پیامدها
- جمعیت
- بیماران (متن ذکر نشده)
- مداخله/مواجهه
- سوند میانی (MC)
- مقایسه
- متن ذکر نشده
- حجم نمونه
- متن ذکر نشده
متن کامل اصلی
لینک مستقیم از metadata منبع گرفته شده و در تب جدید باز میشود.
باز کردن متن کامل